Download Operation & user’s manual of CADDX NX-8 Control Panel, Security System for Free or View it Online on All-Guides.com. This version of CADDX NX-8 Manual compatible with such list of devices, as: NX-8, NX-8e, NX6UB98, NX8EUA01, NX8UI00
The GE Caddx Networx line of security systems offer many of the features of more complicated alarms, but at very reasonable prices. The 3 main panels are the GE NX-4, NX-6, and the NX-8. The smallest is the NX-4, with 8 on-board zones. The largest panel is the Caddx NX-8, with 8-zones on-board, expandable to 48. The NX-8-ZA-TK (from now on called NX-8) NetworX from Caddx represents a new approach to the design of security systems. The NX-8 is probably the most flexible, durable, and user-friendly control panel ever seen in our industry. Its features include sophisticated software. Auxiliary Outputs - The NX-8 has four programmable outputs that ca n be used to activate relays, LED=s, etc. (See the terminal description on page 57 and locations 45-50, page 25) Auxiliary Power Overcurrent - The NX-8 will illuminate the 'Service' LED on the keypad whenever too much current is drawn from any device powered by the system.
NX-320E Remote Power Supply NX-216E 16 Zone Expander NX-8 NX-8V2 Control Panel only (48 zones) NX-408E # 8 Zone Wireless Expansion Module (UL LISTED PART #60-904) NX-8-KIT NX-8V2 Control, NX-108E LED Keypad, & 16.5V 40VA Transformer NX-416E # 16 Zone Wireless Expansion Module (UL LISTED PART #60-904). http://www.tsoutingypbo1987.simpsite.nl/ruby-install-for-mac.
How To Program Caddx Nx 8 Wiring Manual
Brand: CADDX
Category: Control Panel , Security System
Type: Operation & user’s manual
Model: CADDX NX-8 , CADDX NX-8e , CADDX NX6UB98 , CADDX NX8EUA01 , CADDX NX8UI00
Pages: 18
SECURITY SYSTEM NOTES
Installing/Service Company _________________________________
For Service Call __________________________________________
Central Station ___________________________________________
FUNCTION CODES
This system is is not partitioned.
Fire Auxiliary Emergency Police
Abort Delay (V) Cancel Alarm Forced Arming (V)
Auto Bypass (V) Change Partitions Group Bypass (V)
Battery Test Communicator Test Re Exit
(V) These features should not be enabled on UL listed systems.
Exit Delay Time __________Secondary Exit Delay Time ________
Entry Delay Time _________Secondary Entry Delay Time _______
01 _______________09 _______________17 _______________
02 _______________10 _______________18 _______________
03 _______________11 _______________19 _______________
04 _______________12 _______________20 _______________
05 _______________13 _______________21 _______________
06 _______________14 _______________22 _______________
07 _______________15 _______________23 _______________
08 _______________16 _______________24 _______________
Related Products for CADDX NX-8
Related Manuals for CADDX NX-8
CADDX NX-8: Frequently viewed Manuals
Hi Mike,Do you want to do a 'factory default' on the NX-8 panel? Windows usb dvd download tool for mac. If that is what
you want to do, click the following link for the manual. Go to page 8 and
follow the instructions for 'Loading Factory Defaults' in the center of the
page.
you want to do, click the following link for the manual. Go to page 8 and
follow the instructions for 'Loading Factory Defaults' in the center of the
page.
NOTE: Doing this will clear the program, requiring you to program the entire
system from scratch. Please be absolutely certain this is what you want to
do before doing so.
system from scratch. Please be absolutely certain this is what you want to
do before doing so.
If all you want is to change the Download Access Code, that is stored in
Location 20. Follow the instructions for changing that value alone.
Location 20. Follow the instructions for changing that value alone.
Networx Nx 8 Manual
Another significant code is the 'Go To Program' code, found in location 42.
It's a 4- or 6-digit code. This is the code you use to enter programming
mode.
It's a 4- or 6-digit code. This is the code you use to enter programming
mode.
To change any item, enter programming as follows:
Disarm the system.
Press [*]-[8].
Enter the current 'Go To Program' code.
Press [0]-[#] to program functions of the NX-8 master control panel itself.
Enter the location number you wish to display/alter, followed by the [#]
key.
Enter the desired new data, followed by the [*] key.
After you press the [*] key the program will advance to the next segment.
Change it if needed and press [*] to scroll on.
Press [*]-[8].
Enter the current 'Go To Program' code.
Press [0]-[#] to program functions of the NX-8 master control panel itself.
Enter the location number you wish to display/alter, followed by the [#]
key.
Enter the desired new data, followed by the [*] key.
After you press the [*] key the program will advance to the next segment.
Change it if needed and press [*] to scroll on.
How To Program Caddx Nx 8 Wiring Diagram
For more detailed instructions, see page 9 of the manual I referenced above.
Regards,
Robert L Bass
Robert L Bass
>
Bass Home Electronics
The Online DIY Alarm Store
http://www.Bass-Home.com
4883 Fallcrest Circle
Sarasota, FL 34233
877-722-8900 Sales & Tech Support
941-925-9747 voice (Florida)
941-923-6238 fax
[email protected]
>
Bass Home Electronics
The Online DIY Alarm Store
http://www.Bass-Home.com
4883 Fallcrest Circle
Sarasota, FL 34233
877-722-8900 Sales & Tech Support
941-925-9747 voice (Florida)
941-923-6238 fax
[email protected]
>